EasyManua.ls Logo

Groen BPM-30GC - User Manual

Groen BPM-30GC
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
This manual provides information for:
OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
PART NUMBER 174839, REV. D (12/17)
MODELS
BPM-15/30/40G(C,A)
& BPP-30/40G(C,A)
Domestic
ERGONOMIC TILTING
BRAISING PAN
· Stainless Steel
· Manual or Power Tilt
· Gas Heated
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this or any other appliance.
POST IN A PROMINENT LOCATION
Instructions to be followed in the event user smells
gas. This information shall be obtained by consulting
your local gas supplier. As a minimum, turn o the gas
and call your gas company and your authorized service
agent. Evacuate all personnel from the area.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unied Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to le
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net

Questions and Answers

  • S
    Steven GarzaAug 17, 2025
    Why won't the main burner come on in my Groen BPM-30GC Commercial Food Equipment even though the pilot light is on and the spark stays on?
    • C
      Caleb ArmstrongAug 18, 2025
      If the pilot light is on, but the main burner of your Groen Commercial Food Equipment won't ignite and the spark remains on, you should check for improper grounding and repair it with high-temperature wire if necessary. Inspect the pilot burner ceramic insulator for cracks. Ensure that the high tension cable isn't grounded out; correct this if it is. Verify proper gas pressure. Clean the pilot assembly or replace it if needed. Tighten all mechanical and electrical connections. If the issue persists, consider replacing the ignition control module.
  • J
    Jamie SimpsonAug 20, 2025
    What to do if spark is present but the pilot will not light on Groen BPM-30GC Commercial Food Equipment?
    • D
      donaldwilliamsAug 20, 2025
      If there is a spark, but the pilot light on your Groen Commercial Food Equipment won't ignite, ensure the pilot valve is securely connected to the terminals. Check for 24 VAC at the PV terminals to ground; if it's not present, replace the ignition control module. Verify that the gas pressure is at least 3.5” W.C. (8.7 millibars). Check for gas flow at the pilot: examine the pilot gas line for kinks or obstructions, clean the orifice if necessary, and check the solenoid operation of the pilot valve on the gas valve, repairing or replacing as needed. Ensure the pilot spark gap is located in the pilot gas stream; adjust or replace the pilot burner if it's not. Finally, check for drafts and shield the pilot burner if necessary.
  • D
    David NguyenAug 22, 2025
    Why does the main burner come on but will not stay on in my Groen BPM-30GC Commercial Food Equipment?
    • K
      Katelyn WilsonAug 22, 2025
      If the main burner of your Groen Commercial Food Equipment ignites but doesn't stay on, inspect the burner ground for damaged wires or loose connections, replacing with high-temperature wire if necessary. Also, check for low gas supply pressure. If the issue persists, consider replacing the ignition control module.
  • J
    Joshua VillarrealAug 26, 2025
    How to fix a Groen BPM-30GC when it does not produce a spark?
    • N
      Nathan PeckAug 26, 2025
      If your Groen Commercial Food Equipment isn't producing a spark, check the controller to ensure it's energized. Verify the AC voltage between the terminals on the secondary side of the transformer; if it's not 24 Volts, replace the transformer. Make sure the high tension cable is in good condition; replace it if cracked or brittle. Inspect the pilot electric ceramic for cracks or breaks and check the pilot spark gap, re-gapping if necessary.
  • E
    Erik JonesAug 27, 2025
    What to check if burners will not light on Groen BPM-30GC?
    • S
      Shirley BrownAug 27, 2025
      If the burners on your Groen Commercial Food Equipment won't light, ensure that the main gas supply valve is open (handle in line with the gas pipe). Confirm that the gas supply to the braising pan is at the specified pressure and that the pan body is horizontal.
  • B
    Brian EllisAug 30, 2025
    Why does pilot flame go out when Combination Control knob is released on Groen BPM-30GC Commercial Food Equipment?
    • C
      Catherine MorrisAug 30, 2025
      If the pilot flame goes out when the Combination Control knob is released on your Groen Commercial Food Equipment, check the pilot gas adjustment. Ensure the connections from the Powerpile generator to the Pilotstat power unit and Powerpile operator are clean and secure. Determine if the open and closed circuit output voltages of the generator are within the acceptable range shown by the charts in the manual for the W720 Systems Tester. Also, check the resistance of the Pilotstat power unit. If an appropriate meter is unavailable, replace the generator first, then the power unit.
  • L
    Laura OrtegaSep 1, 2025
    What to do if pan will not heat, and pilot light is out on Groen BPM-30GC?
    • S
      Stephanie JohnsonSep 2, 2025
      If your Groen Commercial Food Equipment pan will not heat and the pilot light is out, check if the Combination Gas Control Valve knob is turned ON. Also, inspect the pilot tubing and orifice for any clogging.
  • A
    Anthony CookSep 4, 2025
    Why does the pan continues to heat after it reaches desired temperature on Groen BPM-30GC Commercial Food Equipment?
    • B
      Brian ColemanSep 4, 2025
      If your Groen Commercial Food Equipment pan continues to heat after reaching the desired temperature, check the temperature controller dial setting and display.
  • K
    Kimberly RobertsSep 7, 2025
    How to fix uneven heating in my Groen Commercial Food Equipment pan?
    • D
      David CruzSep 7, 2025
      If your Groen Commercial Food Equipment pan heats unevenly, ensure that the pan body is horizontal. Also, make sure that the pan is preheated properly in accordance with the instructions in the Operation section of this manual.
  • G
    garymorenoSep 9, 2025
    What to do if pan will not heat, but pilot light is burning on Groen BPM-30GC Commercial Food Equipment?
    • M
      Mr. Gregory Rowe Jr.Sep 9, 2025
      If your Groen Commercial Food Equipment pan will not heat, but the pilot light is burning, ensure that the secondary thermostat switch is closed.

Summary

Operator Manual Introduction and Safety

General Safety Warnings

Key safety precautions and warnings to prevent injury or damage.

Equipment Overview and Specifications

Equipment Description

Detailed description of the braising pan's construction and features.

Installation and Initial Operation

Installation Procedures

Step-by-step guide for installing the braising pan according to codes.

Operation and Cooking

Operator Controls

Explanation of the control panel buttons, knobs, and indicators.

Operating Procedures

How to tilt, start, stop, and manage the unit during operation.

Cooking and Preheating

Guidance on preheating the pan and cooking methods.

Sequence of Operation, Cleaning, and Maintenance

Troubleshooting

Troubleshooting Guide

Common issues, symptoms, and recommended checks or solutions.

Schematics and Diagrams

Groen BPM-30GC Specifications

General IconGeneral
ModelBPM-30GC
CategoryCommercial Food Equipment
Capacity30 gallons
Power SourceGas
MaterialStainless Steel
Control TypeManual
Exterior FinishStainless Steel