27
28
The internal structure of the DIP switch is as the following figure:
6.3.2 DIP switch option corresponding to the country
DANGER
When you setting the DIP, you must turn off the AC breaker and DC
breaker.
Information
After setting the DIP, please power on the inverter and check the
model display. If the last character of the model name is
corresponding to the country safety standard as the above table, it
means your setting is successful.
You should change the time displayed on the LCD of inverter to
your local time after inverter starts up.
If the country is set incorrectly, please shut down the inverter
and set again.
When the cables of AC side and DC side are all well connected, before
commissioning, the country safety standard must be selected by the DIP switch.
The DIP switch is composed of four-digit binary number PINS. The different
combination of the four PINS can represent different inverter's model, which is
corresponding to the local grid standard. Each small white PIN has two statuses,
when set upward to 'ON', its value turns to '1', when set downward, its value turns
to '0'. Concerning the matching of the PIN status and the country safety standard,
please refer to the table below:
Switch to country table 6.3.1
DIP switch status Country Model display
VDE 0126 GTXXXXXXX1
G59-3
GTXXXXXXX2