- 10 -
ADVANCED FEATURES
COLD STARTUP
When the battery temperature is -30~-20℃ (-22~-4℉) and connected to a solar panel under sunshine or AC input, the portable power
station can automatically heat the battery to operating temperature for normal use.
Remaining heating time/min
-20℃ (-4℉) (minimum discharging temperature)
0℃ (32℉) (minimum charging temperature)
*Notice:
1. This remaining heating time is calculated under optimal charging efficiency and is for reference only. The heating function will stop after
the battery temperature reaches 5℃ (41℉).
2. Remaining heating time: the time required to heat the current battery temperature to 5℃ (41℉). For example, if the current battery
temperature is -20℃ (-4℉), the time required to heat to 5℃ (41℉) is 65 minutes.
INFINITY 2000 DETACHABLE TROLLEY
The INFINITY 2000 Expansion Battery can be used with a trolley to meet users' needs for easy transportation of the portable power station.
(See the trolley manual for details)