Press the touch key 5S, the OLED shows Country setting is complete.
When the Country setting is complete, the OLED display shows “Set Region” as
below:
We can
set Region A,B or C when you choose Australia,but if you choose
Newzealand the default Region is NZ.
When Region A is selected, the inverter loads all the Region A values for power
quality response modes and grid protection settings.
7.1.3 Enabling/Disabling Power Quality Response Modes
(PQRM)
Information
PQRM setting
When the Region setting is completed, the inverter will operate
under default mode different from region.
MIN TL-X contains five types Power Quality Response Modes:
Volt-Var, Volt-watt, Fixed PF, Reactive power, Power limit.If you want to change the
Power Quality Response Modes please refer to chapter 7.3.1.
7.1.4 Check firmware version,Region,Country/Area and
Power
Quality Response Modes
Single touch to sw
itch display
.
Double touch to enter next stage menu.