39
Active power control and reactive power control are enabled separately.
6.9 AFCI(Optional)
6.9.1 Arc-Fault Circuit Interrupter (AFCI)
In accordance with the National Electrical Code R, Article 690.11, the inverter has a
system for the recognition of electric arc detection and interruption. An electric arc
with a power of 300 W or greater must be interrupted by the AFCI within the time
specified by UL 1699B. A tripped AFCI can only be reset manually. You can eactivate
the automatic arc fault detection and interruption (AFCI) via a communication
roduct in "Installer" mode if you do not require the function. The 2011 edition of the
National Electrical Code R, Section 690.11 stipulates that newly installed PV systems
attached to a building must be fitted with a means of detecting and disconnecting
serial electric arcs (AFCI) on the PV side.
6.9.2 Danger information
Danger of fire from electric arc
Only test the AFCI for false tripping in the order described below.
Do not deactivate the AFCI permanently.
If an "Error 200" message is displayed, the buzzer alarms, an electric arc occurred in
the PV system. The AFCI has tripped and the inverter is in permanent shutdown.
The inverter has large electrical potential differences between its conductors. Arc
flashes can occur through air when high-voltage current flows. Do not work on the
product during operation.
When the inverter error 200, please follow the steps:
6.9.3 Operation step
6.9.3.1 Turn the DC & AC Disconnect to position "oFF".