EasyManua.ls Logo

Growatt MID 17KTL3-XH User Manual

Growatt MID 17KTL3-XH
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Download
Manual
Growatt New Energy
Installation
&
Operation Manual
GR-UM-320-A-00
Shenzhen Growatt New Energy Co., Ltd
4-13/F, Building A, Sino-German (Europe) Industrial Park,
Hangcheng Ave, Bao’an District, Shenzhen, China
+86 755 2747 1942
www.ginverter.com
T
E
W
service@ginverter.com

Questions and Answers:

Growatt MID 17KTL3-XH Specifications

General IconGeneral
ModelMID 17KTL3-XH
Rated Power17000W
Max DC Input Voltage1100V
Start Voltage200 V
Nominal DC Voltage600 V
Number of MPPT2
Max. Short Circuit Current per MPPT15 A
Nominal AC Power17000W
Nominal Grid Frequency50/60Hz
THDi< 3%
Protection ClassIP65
DC SwitchYes
AC Surge ProtectionType II
DC Surge ProtectionType II
TopologyTransformerless
THD< 3%
Max. DC Power22000 W
Input Voltage Range200 V - 1, 000 V
Max. AC Power17.6 kW
Max. AC Apparent Power17000VA
Nominal AC Voltage230V/400V
Power Factor0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to 60°C
CommunicationRS485
Max. DC Input Power22000 W

Summary

Safety

Safety Instructions and Warnings

Provides crucial safety guidelines for installation, electrical connection, and operation.

Installation

Basic Installation Requirements

Lists essential prerequisites and conditions for installing the inverter.

Wall-Mounted Installation

Details the process of mounting the inverter on a wall.

Installing the Inverter

Describes how to securely attach the inverter to the mounting bracket.

Electrical Connection

Precautions for Electrical Connection

Highlights critical safety measures before making electrical connections.

AC Side Wiring

Explains the procedure for connecting the AC power output.

DC Side Wiring

Details the process of connecting the DC input from PV panels.

Connecting Bidirectional DC/DC Box

Provides instructions for connecting the DC/DC box for battery management.

Connecting the Signal Cable

Guides on how to connect the communication signal cable.

Grounding the Inverter

Explains the correct method for grounding the inverter for safety.

Backup Function (Optional)

Explains how to enable and use the backup power mode.

Commissioning

Commissioning Steps

Outlines the procedure for the initial setup and self-check.

OLED Display and Touch Button

Communication and Monitoring

Powering On/Off the Inverter

Troubleshooting

Error Message Information

Lists information required for technical assistance with error messages.

System Warnings and Solutions

Provides troubleshooting steps for various system warning messages.

System Errors and Solutions

Details system error codes and their corresponding resolution steps.

Decommissioning

Specifications