11 Manufacturer Warranty
Please refer to the warranty card.
12 Decommissioning
12.1 Dismantling the Inverter
1 Disconnect the inverter as described in section 8 .
2 Remove all connection cables from the inverter.
CAUTION
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has cooled down.
3 Screw off all projecting cable glands.
4 Lift the inverter off the bracket and unscrew the bracket screws.
12.2 Packing the Inverter
If possible, always pack the inverter in its original carton and secure it with tension
belts. If it is no longer available, you can also use an equivalent carton. The box must
be capable of being closed completely and made to support both the weight and the
size of the inverter.
12.3 Storing the Inverter
Store the inverter in a dry place where ambient temperatures are always between
-25°C and +60°C.
12.4 Disposing of the Inverter
Do not dispose of faulty inverters or accessories together with household
waste. Please accordance with the disposal regulations for electronic waste
which apply at the installation site at that time. Ensure that the old unit and,
where applicable, any accessories are disposed of in a proper manner

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MIN 3000 TL-X and is the answer not in the manual?

Growatt MIN 3000 TL-X Specifications

General IconGeneral
Rated Output Power3000 W
Max. DC Power4500 W
Max. PV Input Power4500 W
Max. Output Power3000 W
Nominal DC Voltage360 V
Number of MPPT2
Number of MPPTs2
Max. Short Circuit Current per MPPT15 A
Nominal AC Power3000 W
Max. AC Power3000 W
Nominal AC Voltage230 V
AC Voltage Range180-280V
Output Voltage230 V
THDi< 3%
DC Connection TypeMC4
Protection DegreeIP65
Operating Temperature Range-25 °C to +60 °C
CoolingNatural Cooling
Cooling MethodNatural Cooling
Weight14 kg
Protection LevelIP65
Nominal Grid Frequency50 Hz
Output Frequency50 Hz
AC Connection TypePlug