21
15
Alarm control
Alarm on (default)
Alarm off
16
Backlight control
Backlight on (default)
Backlight off
17
Beeps while primary
source is interrupted
Alarm on (default)
Alarm off
19
C.V. charging voltage
If self-defined is
selected in program 5,
this program can be set
up
48V model: default 56.4V, 48.0V~58.4V Settable
20
Floating charging
voltage.
If self-defined is
selected in program 5,
this program can be set
up
48V model: default 54.0V, 48.0V~58.4V Settable
21
Low DC cut-off voltage.
If self-defined is
selected in program 5,
this program can be
set up
48V model: default 42.0V, 40.0V~48.0V Settable
Lithium battery mode: default 20%, 5%~50% Settable
22
RS485
communication address
Default 001,001-255 Settable
23
Battery equalization
Disabled (Default)
Enable
If Flooded or User-Defined is selected in program this
program can be set up.