Start-up/commissioning
33 | 64
BA_712940
-inter_175_GENO
-Multi Nive
au.docx
6.2 Setting the control unit
In case other tanks (except GT 1000) are used, the parameters
Filling level, Filling height and Filling volume must be adapted.
The filling volume is defined as the amount of water between the
bottom and the upper edge of the overflow in the tank.
The switching points and the hysteresis of the programmable con-
tacts as well as the switching point of the alarm contact (= switching
point of the solenoid valve) must be adapted to the on-site require-
ments (refer to chapter 7.2).
Only correct the measuring range if a different level probe
other than the standard level probe with 0.25 bar (2.5 mWC)
is used.
6.3 Handing over the product to the owner/oper-
ator/operating company
Explain to the owner/operator/operating company how the
product works.
Use the manual to brief the owner/operator/operating com-
pany and answer any questions.
Inform the owner/operator/operating company about the
need for inspections and maintenance.
Hand over all documents to the owner/operator/operating
company for keeping.