10. Fault finding the product
WARNING
Electric shock
Death or serious personal injury
Switch of
f the power supply before you
start any work on the product.Make
sure that the power supply cannot be
switched on accidentally.
WARNING
Moving parts
Death or serious personal injury
T
ighten the coupling screws to the cor-
rect torque.
Install the coupling guards securely to
the pump with the screws intended for
this purpose.
CAUTION
Corrosive liquids
Minor or moderate personal injury
W
ear personal protective equipment.
CAUTION
T
oxic liquids
Minor or moderate personal injury
Wear personal protective equipment.
CAUTION
Hot or cold liquid
Minor or moderate personal injury
W
ear personal protective equipment.
CAUTION
Hot or cold surface
Minor or moderate personal injury
Make sure that no one can accidentally
come into contact with hot or cold sur-
faces.
Related information
8.3.1 Periodic checks
10.1 The motor does not run when started.
Cause Remedy
Power supply failure. Connect the power supply.
One or more fuses are blown. Replace the fuses.
The motor-protective circuit breaker has tripped. Reactivate the motor-protective circuit breaker.
The thermal protection has tripped. Reactivate the thermal protection.
The main contacts in the motor-protective circuit
breaker are not making contact, or the coil is faulty
.
Replace the contacts or the magnetic coil.
The control circuit is defective. Repair the control circuit.
The motor is defective. Replace the motor.