EasyManua.ls Logo

Grundfos NB Series - Motor Without Feet; 5 Pump Without Motor

Grundfos NB Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
5. Pump without motor
5.1 Motor without feet
NB and NBG pumps are available without motor. The pumps are
supplied as complete pumps with a transport bracket protecting
the shaft seal during transport. When you mount the motor, follow
the instructions shown in these drawings.
TM03 3913 1206
TM03 3906 1206
1. Remove the coupling guard and loosen the hexagon socket
head screws in the shaft.
2. Place the pump on the motor.
TM03 3907 1206
TM03 3908 1206
3. Fit and tighten the hexagon head screws. 4. Remove the nut, washer and transport bracket.

Other manuals for Grundfos NB Series

Related product manuals