* ΣF and ΣM are the vector sums of the forces and torques.
If not all loads reach the maximum permissible value,
one of the values is allowed to exceed the normal
limit. Contact Grundfos for further information.
Stainless
steel
Diameter
DN
Force [N] Torque [Nm]
Fy Fz Fx ΣF * My Mz Mx ΣM *
Horizontal
pump,
z-axis,
discharge port
32 595 735 630 1155 525 595 770 1120
40 700 875 770 1365 630 735 910 1330
50 945 1155 1050 1820 700 805 980 1435
65 1190 1470 1295 2310 770 840 1050 1540
80 1435 1750 1575 2765 805 910 1120 1645
100 1890 2345 2100 3675 875 1015 1225 1820
125 2240 2765 2485 4340 1050 1330 1470 2135
150 2835 3500 3150 5495 1225 1435 1750 2555
Horizontal
pump,
x-axis,
suction port
50 1050 945 1155 1820 700 805 980 1435
65 1295 1190 1470 2310 770 840 1050 1540
80 1575 1435 1750 2765 805 910 1120 1645
100 2100 1890 2345 3675 875 1015 1225 1820
125 2485 2240 2765 4340 1050 1330 1470 2135
150 3150 2835 3500 5495 1225 1435 1750 2555
200 4200 3780 4690 7315 1610 1855 2275 3360