Product Name | Grundfos SCALA1 System |
---|---|
Category | Water Pump |
Power Consumption | 1.1 kW |
Max Head | 45 m |
Max Operating Pressure | 10 bar |
Protection Class | IP42 |
Weight | 12.5 kg |
Maximum Suction Lift | 8 m |
Inlet/Outlet Size | 1 inch |
Housing Material | Composite |
Liquid Temperature Range | 0°C to +45 °C |
Pump Type | Self-priming centrifugal pump |
Approvals | CE, EAC |
Installation Type | Horizontal |
Operating Temperature Range | 0°C to +60°C |
Max Flow Rate | 4.2 m³/h |
Control Panel | Built-in control panel with LED indicators |
Explains hazard symbols and statements used in the manual.
Explains the meaning of various symbols and notes found in the document.
Identifies the intended users for these installation and operating instructions.
Details the purpose and functionality of the SCALA1 System.
Specifies the types of liquids compatible with the pump and liquids to avoid.
Provides instructions and requirements for mounting the system on a wall.
Step-by-step guide for securely attaching the pump unit to a wall.
Instructions for correctly installing the overflow pipe for proper drainage.
Guidance on connecting the mains water supply to the system.
Steps for connecting the pipe from the rainwater storage tank.
Details on how to connect the pipe that delivers water from the pump.
Instructions for correctly installing the float switch within the rainwater tank.
Step-by-step instructions for filling the pump with water before initial operation.
Guide on powering on and initiating the pump's first operation.
Explains the overflow alarm, its triggers, and the reset procedure.
Explains the controls, indicators, and buttons on the pump's interface.
Details the automatic reset function for alarms and its configuration settings.
Explains the system's safety feature to prevent operation without water.
Describes the function preventing frequent pump starts and stops due to minor leaks.
Explains the timer function that limits continuous pump operation duration.
Provides instructions for changing the pump's operating mode for optimal performance.
Explains the meaning of different indicator light combinations on the Grundfos Eye.
Lists common causes and remedies when the pump fails to initiate.
Troubleshooting steps for pump stoppage with active dry-running indicator.
Explains reasons and solutions for the pump starting and stopping too often.
Troubleshooting steps for when the pump fails to shut off after demand ceases.
Lists causes and remedies for the pump not delivering adequate pressure or flow.
Explains reasons for pump stoppage due to external input or calendar functions.
Troubleshooting for pump stoppage due to exceeding the maximum operational runtime.
Troubleshooting for pump stoppage when a system leakage is detected.
Diagnoses issues when the pump is off and the Grundfos Eye shows red flashing lights.
Troubleshooting for when the pump is running but shows a red motor indicator light.
Explains reasons and remedies for the pump stopping unexpectedly during use.
Important safety warning regarding electrical hazards during installation and operation.
Methods for clearing and resetting fault alarms and indications on the pump.
Outlines recommended preventative maintenance activities for the system.
Step-by-step guide for cleaning the pump's internal filter assembly.
Lists the operating parameters and environmental conditions for the SCALA1 system.
Provides mechanical details such as pipe connection sizes and materials.
Details electrical parameters including voltage, power consumption, and current ratings.
Lists the physical dimensions and weight of the different SCALA1 pump models.
Guidance on the safe and environmentally responsible disposal of hazardous substances.