Loading...
6.11 The pump is not running and Grundfos
Eye is flashing red
Grundfos Eye:
Two opposite red
indicator lights are
flashing simultaneously.
Cause Remedy
The shaft seal is seized
up.
Dismantle the pump.
Remove the impurities.
The pump is blocked by
impurities.
Inspect the pump for
signs of blockage, and
remove any impurities.
Overheating due to
seized-up or choked-up
pump.
Contact your pump
supplier.
Too low or too high
supply voltage.
Check the supply
voltage and correct the
fault, if possible.
6.12 The pump is running and the motor
shows a red indicator light
Grundfos Eye:
Two opposite green
indicator lights are
rotating.
The leakage indicator
light is on.
Cause Remedy
The non-return valve is
not properly closed or
the pipe system is
leaking. This happens
when cycling alarm
and/or leakage alarm
are disabled.
Check and repair the
pipe system, or clean,
repair or replace the
non-return valve.
Small continuous
consumption.
Make sure that all taps
are closed.
Check the system for
leakages.