2. Product introduction
2.1 Product description
The SCALA1 System is used to manage and
distribute rain. The system is suitable for irrigation,
water flushing of toilets and floor cleaning systems.
The system prioritises the use of rainwater over tap
water. In case of insufficient rainwater in the tank, the
control unit switches to tap water to ensure the
necessary water flow at the tapping points. The
system automatically switches between the rainwater
tank and the tap water tank by means of a three-way
valve installed on the pump inlet port. The water
supplied by the system is not potable.
2.2 Pumped liquids
DANGER
Explosion risk
Death or serious personal injury
Do not use the product for flammable
liquids such as diesel oil, petrol or
similar liquids. The product must only
be used for water.
WARNING
Electric shock
Death or serious personal injury
Do not use the product for aggressive
liquids. The product must only be used
for water.
WARNING
Toxic material
Death or serious personal injury
Do not use the product for toxic liquids.
The product must only be used for
water.
If the water contains sand, gravel or other
debris, there is a risk of pump blockage
and pump damage. Install a filter on the
inlet side or apply a floating strainer to
protect the pump.
The product is suitable for pumping clean, thin, non-
aggressive and non-explosive liquids without solid
particles or fibres.
The product is designed for fresh water with a
maximum chloride content of 300 ppm and a free
chlorine content below 1 ppm.
Examples of liquids:
clean water
rainwater.
3. Mechanical installation
WARNING
Electric shock
Death or serious personal injury
Switch off the power supply before you
start any work on the product. Make
sure that the power supply cannot be
switched on accidentally.
WARNING
Electric shock
Death or serious personal injury
Mount the product horizontally to avoid
condensation in the electrical insulation
inside the control box.
WARNING
Chemical hazard
Death or serious personal injury
Before the pump is used for supplying
drinking water, flush the pump
thoroughly with clean water.
WARNING
Biological hazard
Death or serious personal injury
Before the pump is used for supplying
drinking water, flush the pump
thoroughly with clean water.
6