GUIL - TORO lifters
27
www.guil-lifters.com - GUIL
-
7.- Put the forks into the horizontal position and secure them using the magnetic locking bolts.
8.- Place the load on the forks.
IMPORTANT: When the TORO tower is raised over 6.5 m the minimum load is 50 kg.
9.- With the load on the lifter ensure it is levelled. If not, adjust the levelling jacks on the legs until it is.
REVERSING THE FORKS
1.- Pull out the magnetic locking bolts.
2.- Remove the forks.
3.- Remove the nut and bolt that holds the fork bracket to the
carriage.
4.- Turn the fork bracket 180º, insert back it onto the carriage and
secure the nut and bolt again.
5.- Install the forks in the working position.
When the forks are in the working position they should
slope slightly upwards.
6.- Secure using the magnetic locking bolts.
FUNCTION TEST
1.- Place a load on the forks of the lifter.
2.- Raise and lower the lifter to check the following functions.
2.1.- Check that the winch is working correctly:
2.1.1.- It must operate smoothly and free of hesitation, binding or strange noises.
2.1.2.- All components must be present.
2.1.3.- And above all it, must brake perfectly.
FORK
CARRIAGE
MAGNETIC
LOCKING BOLT