REMOTE CONTROL
VSET<X>?
Description
Returns the output voltage setting.
X
1: CH1, 2: CH2, (4303S: 3: CH3, 4: CH4)
Response time
Minimum 10ms
Example VSET1?
Returns the CH1 voltage setting
IOUT<X>?
Description
Returns the actual output current.
X
1: CH1, 2: CH2, (4303S: 3: CH3, 4: CH4)
Response time
Minimum 10ms
Example IOUT1?
Returns the CH1 output current
VOUT<X>?
Description
Returns the actual output voltage.
X
1: CH1, 2: CH2, (4303S: 3: CH3, 4: CH4)
Response time
Minimum 10ms
Example VOUT1?
Returns the CH1 output voltage
TRACK<NR1>
Description
Selects the operation mode: independent, tracking
series, or tracking parallel.
NR1
0: Independent, 1: Series, 2: Parallel
Response time
Minimum 10ms
Example TRACK0
Selects the independent mode