Do you have a question about the GW Instek GPS-4303 and is the answer not in the manual?
General operating environment, storage, and accessories.
Details on independent, series, and parallel operation modes.
Specifications for constant voltage output range and regulation.
Specifications for constant current output range and regulation.
Specifications for tracking operation, series and parallel.
Information on meter display and accuracy specifications.
Detailed specifications for the CH3 output channel.
Detailed specifications for the CH4 output channel.
Insulation specifications for chassis and terminals.
Description of controls and indicators on the front panel.
Description of controls and indicators on the rear panel.
Safety precautions for operating the power supply.
Procedure for setting the output current limit.
Explanation of the crossover characteristics of the supply.
How to use the different operation modes (Independent, Series, Parallel).
Procedure for replacing the fuse.
How to convert the unit for different line voltages.
Procedures for calibrating and adjusting the power supply.
Instructions for cleaning the power supply.
General operating environment, storage, and accessories.
Details on independent, series, and parallel operation modes.
Specifications for constant voltage output range and regulation.
Specifications for constant current output range and regulation.
Specifications for tracking operation, series and parallel.
Information on meter display and accuracy specifications.
Detailed specifications for the CH3 output channel.
Detailed specifications for the CH4 output channel.
Insulation specifications for chassis and terminals.
Description of controls and indicators on the front panel.
Description of controls and indicators on the rear panel.
Safety precautions for operating the power supply.
Procedure for setting the output current limit.
Explanation of the crossover characteristics of the supply.
How to use the different operation modes (Independent, Series, Parallel).
Procedure for replacing the fuse.
How to convert the unit for different line voltages.
Procedures for calibrating and adjusting the power supply.
Instructions for cleaning the power supply.
| Output Channels | 3 |
|---|---|
| Power | 195W |
| Voltage Resolution | 10 mV |
| Current Resolution | 1 mA |
| Display Type | LED |
| Output Current | 0-3A |
| Ripple and Noise (CV) | < 1mVrms |
| Load Regulation (CV) | ≤ 0.01% + 5 mV |
| Line Regulation (CV) | ≤ 0.01% + 5 mV |
| Interface | USB, RS232 |
| Operating Temperature | 0 to 40 °C |
| Storage Temperature | -20 to 70 °C |