OPERATION
93
4. If there are no errors during loading, the script
engine will enter the wait state. The wait state
indicates that the unit is ready to execute the
script.
5. To execute the script, press the
Output key. The Output key
becomes illuminated.
When the script is executing,
the measurement results will
display as normal.
The Test LED will flash.
When a script is running, press the Output key
again to return the script engine to the wait state.
When a script is running, press the Test key to
abort the execution of the script and return to
normal operating mode. The Test LED will led turn
off after the script has been aborted.
Error messages: If you try to run a test script from
an empty memory location “Err 003” will be
displayed on the display.