PSW Series User Manual 
76 
Master-Slave Parallel Connection 
 
The Analog Control Connector is used for both 
serial and parallel connections. The way the 
connector is configured determines the 
behavior of the master and slave units. For the 
complete connector pin assignment, see page 
120.   
Analog Connector 
Connection 
To operate the power supplies in parallel, 
connect the analog connectors on the master 
and slave units as shown in the diagrams 
below.  
Alternatively pre-configured cables (optional) 
can be used. The PSW-006 is used for two units 
in parallel. The PSW-007 is used for 3 units in 
parallel. 
Master with 2 slave units: 
12
13
14
1517
20
21
24 20 12
17 15 3 17 15
3
12
24 20
11 1
2
1
OUTPUT ON STATUS21
Master unit
ALM STATUS20
STATUS COM17
FEEDBACK15
CURRENT_SUM_113
SHUTDOWN12
OUT ON/OFF CONT24
Slave Unit 1
12 SHUTDOWN
20 ALM STATUS
15 FEEDBACK
3 CURRENT SUM OUT
Slave Unit 2
OUT ON/OFF CONT24
12 SHUTDOWN
17 STATUS COM 17 STATUS COM
2 D COM
15 FEEDBACK
CURRENT_SUM_2 CURRENT SUM OUT314
20 ALM STATUS
11 1 1I MON CURRENT SHARE CURRENT SHARE
16 16 16
 A COM16 16 A COM 16 A COM
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com