光毓机电 RMD-X8
V1.0
Note:
1. Acceleration option does not take effect in the current version of the drive, and the
actual Acceleration of the motor depends on the PI parameters,motor load and drive
voltage, etc.
2. After the parameters are modified, click the Write button to save the parameters to
the driver.
3. After setting, the new parameters need to be recharged to take effect.
4.3.3 Encoder Setting
In the Encoder page, click the Read button to get the motor and encoder information.
Motor Poles:Set the number of magnetic poles of the motor, generally it will be set
before out of the factory.
Encoder Type:this parameter is read-only.
Motor/Encoder Ratio:The ratio of motor and encoder calibration, which is a
read-only parameter, is generally around 1000. The closer it is to 1000, the better the
calibration effect will be.
Motor/Encoder Offset:The 0 offset of motor and encoder calibration, which is a
read-only parameter, generally has no effect on motor drive performance.