26
GYSPOT ARCPULL 200
EN
CONFIGURATION
Configuration
> Pregaz > 0.2s
Postgaz 0.2s
Langue FR
Reset machine
Info
Press the keys G+ and G- to move the left cursor (Pregas, Postgas, Language, Reset
machine, Info).
When the items Pregas, Postgas or Language are highlighted, press the keys D+ and D-
to modify their value.
Range of settings Comment
Pregas NoGas then from 0.2s to
3s
To weld using a gas coating, it is recommended to have a minimum pre-
gas setting of 0.2s with a ow rate between 10 and 12L/min.
Postgas NoGas or from 0.2s to 3s To weld using a gas coating, it is recommended to have a minimum
postgas setting of 0.2s.
Language FR, GB, DE, NL, ES, IT, RU
Push the return button
to return to the Main Menu
Reset machine
Reset machine
: 3sec
pour valider
When the «Reset Machine» is selected from the Conguration menu, pressing menu/vali-
date
opens the reset machine sub-menu.
Press menu/validate
for 3 seconds to conrm product reset.
Push the return button
to return to the Conguration menu and cancel product reset.
Information panel
Info machine
Soft géné V1.0
Hard géné V2.0
Soft pistolet V1.0
Hard pistolet V2.0
The information panel provides information on software versions and hardware of the gene-
rator and gun (if it is connected).