Make sure to follow the recommended precharge time, depending on the battery capacity.
Product Battery capacity Starting Battery capacity Starting
STARTIUM 330E
50 - 60Ah Instantaneous 60 - 80Ah 5 min pre charge
STARTIUM 480E
50 - 100Ah Instantaneous 100 -160 Ah 5 min pre charge
STARTIUM 680E
50 - 160Ah Instantaneous 160 - 220 Ah 5 min pre charge
STARTIUM 980E
50 - 220Ah Instantaneous 220 - 250 Ah 5 min pre charge
4. Once the precharge is done, go to the vehicle’s dashboard. The «start» feature will activate when the rst attempt
to start is initiated (by turning the key). The attempt time must be for 10 secs maximum (a countdown appears on
the display).
If your engine does not start, wait 2 minutes between each start attempt.
Nb : If the vehicle does not start, it may be a problem other than a faulty battery e.g. alternator, glowplug…
ALTERNATOR TEST
If the vehicle battery is regularly out of order, the problem may come form the alternator.
The STARTIUMS have an «alternator test» feature (
- 12). It can show the alternator’s charge capacity by intermittently
displaying the voltage and the perrcentage.
To use this feature, the vehicle must be started :
1. Connection (p.15).
2. Select the «Test Alternator» function with the selection button ( - 12).
3. The display shows a percentage. It provides information on the alternator’s state of health according to the fol-
lowing table:
Between 0 and a 100% Undercharge fault, the battery is not correctly charged.
At a 100% Alternator all good.
Between a 100% and
200%
Overcharge fault.
PROTECTIONS
These clamps have been designed for maximum protection :
• The charging clamps are fully insulated.
• A fuse guarantees protection against polarity inversion and short circuits. Replacing it requires manual intervention.
STARTIUM 330E STARTIUM 480E / 680E STARTIUM 980E
FUSE
100A
FUSE
200A
FUSE
250A
The thermal protection is monitored by a thermostat (cooling for approximately 1/4h). The fault indicator switches on,
the display shows «th».
If the machine is faulty, an extra thermal protection cuts the machine’s power supply without further indications for
the user. Place the machine in a well ventilated area and wait 15 minutes.
In the event of power supply fault, the machine will enter fault protection mode, The error LED switches on and the
display shows «dEF». If the fault is major, an internal fuse protects the machine. This fuse must be replaced by an
aftersales technician.