EasyManua.ls Logo

H3C MSR3600-28 - Installing a PoE Power Module

H3C MSR3600-28
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
The following are the required terminal settings:
Baud rate9600.
Data bits8.
Stop bits1.
Paritynone.
Flow controlnone.
Installing a power module
IMPORTANT:
The MSR 36-40/36-60 router supports AC power modules, DC power modules, and
PoE power
modules.
The MSR3610-G/3620-G/3600-51/3620-DP router supports AC and DC power modules.
You cannot install AC and DC power modules on the same router.
The MSR 3600 routers support hot swapping of power modules.
Installing an AC/DC power module
1. Face the front of the router and locate the slot to be used.
2. Loosen the captive screws with a Phillips screwdriver to remove the filler panel from the slot.
Keep the removed filler panel for future use.
Skip this step if the router is shipped with this slot empty.
3. Holding the handle of the power module with one hand and supporting the bottom of the power
module with the other hand, insert the power module slowly along the slide rails until it makes
close contact with the backplane.
4. Use a Phillips screwdriver to fasten the captive screws on the two sides of the power module.
Figure 55 Installing an AC power module (MSR 36-40/36-60)

Related product manuals