Do you have a question about the Haas TSC-300/1K and is the answer not in the manual?
Brand | Haas |
---|---|
Model | TSC-300/1K |
Category | Industrial Equipment |
Language | English |
Pressurizes and pumps coolant; auto-clean pneumatic cylinder cleans filter. Vacuum sensor detects clogs.
A one-way valve allowing coolant flow in one direction, preventing backflow when the pump is off.
Creates a vacuum effect to remove excess coolant from the TSC system.
Applies low-pressure air to maintain seals between rotating and non-rotating parts or drawbar.
Use M88 to activate TSC, M89 to deactivate, or press [AUX CLNT].
Graph showing approximate pressure versus tool orifice diameters for TSC 1000 and TSC 300.
Addresses short circuits in pump motor/cable, blown fuses, or tripped breakers.
Details how incorrect power phasing causes the pump motor to run backward.
Covers damage to motor shaft key, collar, or wear in the pump head assembly.
Discusses a defective TSC pressure sensor affecting system readings.
Addresses slow coolant return to tank and low coolant levels.
Covers damaged pressure relief springs and clogged filters/strainers.
Troubleshoots the auto-clean coolant pump filter if it fails to operate.
Verify fuses on the power supply PCB (TSC-300) or circuit breaker (TSC-1K).
Measure pump cable leads to ground to detect short circuits.
Inspect the TSC motor for binding that could cause over-amperage.
Check neon indicators on the power supply PCB for correct power phasing.
Swap incoming power cables at the main transformer if phasing is incorrect.
Rotate pump motor fan and coupling; check for damaged key on motor shaft.
Short sensor leads to check I/O diagnostics bit state.
Use inline gauge to verify pressure after sensor check; replace if over 40 psi.
Remove chips from the auger trough and coolant return drains.
Remove chips from tank, fill tank, and check coolant level sensor.
Remove pump, plugs, and inspect spring and valve pin for damage.
Press plunger to clean; check auto-clean plunger activation and solenoid.
Remove filter retaining ring and screen; clean with soapy water.
Remove chip basket and mesh strainer; clean all chips from the strainer.