288 Y Axis Linear Scale Cable Fault Cable from Y-axis scale does not have valid differential signals.
289 Z Axis Linear Scale Cable Fault Cable from Z-axis scale does not have valid differential signals.
290 A Axis Linear Scale Cable Fault Cable from A-axis scale does not have valid differential signals.
291 Low Air Volume/Pressure During ATC An automatic tool change was not completed due to insufficient
volume or pressure of compressed air. Check air supply line.
302 Invalid R In G02 or G03 Check your geometry. R must be less than or equal to half the
distance from start to end within an accuracy of 0.0010 inches.
303 Invalid X, Y, or Z In G02 or G03 Check your geometry.
304 Invalid I, J, or K In G02 or G03 Check your geometry. Radius at start must match radius at end
of arc within 0.0010 inches.
305 Invalid Q In Canned Cycle Q in a canned cycle must be greater than zero.
306 Invalid I, J, K, or Q In Canned Cycle I, J, K, and Q in a canned cycle must be greater than zero.
307 Subroutine Nesting Too Deep Subprogram nesting is limited to nine levels. Simplify your
program.
309 Exceeded Max Feed Rate Use a lower feed rate.
310 Invalid G Code G code not defined and is not a macro call.
311 Unknown Code Program contained a line of code that is not understood.
312 Program End End of subroutine reached before M99. Need an M99 to return
from subroutine.
313 No P Code In M97, M98, or G65 In M97, M98 or G65 a subprogram number must be put in the P
code. G47 must have P0 for text engraving or P1 for sequential
serial numbers.
314 Subprogram or Macro Not In Memory Check that a subroutine is in memory or that a macro is defined.
315 Invalid P Code In M97, M98 or M99 The P code must be the name of a program stored in memory
without a decimal point for M98 and must be a valid N number for
M99. G47 must have P0 for text engraving or P1 for sequential
serial numbers.
316 X Over Trave1l Range X-axis will exceed stored stroke limits. This is a parameter in
negative direction and is machine zero in the positive direction.
This will only occur during the operation of a user's program.
317 Y Over Travel Range Same as alarm 316.
318 Z Over Travel Range Same as alarm 316.