EasyManuals Logo

Haas VF-4 User Manual

Haas VF-4
564 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #292 background imageLoading...
Page #292 background image
292
PARAMETERS
June 1999
96-8000
Parameter 217 CNVYR IGNORE OC TIM
Amount of time in 1/50 seconds before overcurrent is checked after conveyor motor is turned
on. Default is 50.
Parameter 218 CONVYR RETRY REV TIM
Amount of time that the conveyor is reversed in 1/50 seconds after overcurrent is sensed.
Default is 2000.
Parameter 219 CONVYR RETRY LIMIT
Number of times that the conveyor will cycle through the reverse/forward sequencing when an
overcurrent is sensed before the conveyor will shut down. An overcurrent is sensed when chips
jam the conveyor. By reversing and then forwarding the conveyor, the chip jam may be broken.
Default is 5.
Parameter 220 CONVYR RETRY TIMEOUT
Amount of time in 1/50 seconds between consecutive overcurrents in which the overcurrents is
considered another retry. If this amount of time passes between overcurrents, then the retry
count is set to (0). Default is 1500, 30 seconds.
Parameter 221 MAX TIME NO DISPLAY
The maximum time (in 1/50 sec.) between screen updates.
Parameter 222 ROTARY AXIS INCRMNT
For Horizontal mills only. This parameter sets the degrees of rotation of the A-axis at an M36
or Pallet Rotate.
Parameter 223 AIR TC DOOR DELAY
For Horizontal mills only. This parameter sets the delay to open the tool changer door (in
milliseconds). If the tool changer does not have a pneumatic door, this parameter is set to
zero.
Parameter 224 ROT AXIS ZERO OFSET
This parameter shifts the zero point of A for a wheel fixture or tombstone.
Parameter 225 MAX ROT AXIS ALLOW
For Horizontal mills with a wheel fixture only. This parameter sets the maximum rotation (in
degrees) allowed before stopping at front door.
Parameter 226 EDITOR CLIPBOARD
This parameter assigns a program number (nnnnn) to the contents of the clipboard (for the
advanced editor).
Parameter 227 FLOPPY DIR NAME
When the floppy drive is enabled and a directory is read the directory listing is placed into a
program as comments. The program is then made the current program so the user can read
the contents of the floppy drive. This parameter designates where to write the directory listing.
Program 08999 is the default value.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haas VF-4 and is the answer not in the manual?

Haas VF-4 Specifications

General IconGeneral
CategoryCNC Vertical Machining Center
Z Axis Travel25 in (635 mm)
Spindle Power30 hp (22.4 kW)
Spindle TaperBT-40
Spindle MotorVector drive AC motor

Related product manuals