Page 44 of 62
Brushless DC Controller HST-350
Orginal operating manual Rev1.3
Mounting and commissioning
Without relay
Connection without relay is possible. You will need a suitable cable set for this.
DANGER
The system without relay may only be carried out with batteries suitable for this pur-
pose. The system without relay must never be connected to a power supply unit,
regenerated current can destroy this and cause life-threatening damage.
Example (blue lines represent special wiring harness for application without relay):
Motor
L1
L2
L3
Controller
HST-350
35 pin
connector
CAN-
Adapter
PC
Suitable battery
32,0 - 58,8 VDC
-
L2
L1
L3 +
Dual CAN
V5-Display
Poti
Kl. 15
Sensor cable (optional)