Specification
Domestic air conditioner
TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant
circuit
Refrigerant type R410a
Refrigerant charge lb 2.64
Maximum allowable distance
between indoor an outdoor
in 49.2
Maximum allowable level difference in 32.8
Refrigerant control Capillary
Piping connections
(external diameter)
liquid in Φ0.02
gas in Φ0.03
drain in Φ0.05
Heat insulation type Both liquid and Gas pipes
Max. piping Length in 49.2
Max. vertical Difference in 32.8
Chargeless in 32.8
Amount of Additional Charge of Refrigerant g/in 65.6
Intemational Protection degree IP 24
Note: the data are based on the conditions shown in the table below
htgnel gnipiP gnitaeh gnilooc
Indoor: 80.6°
F
DB/66.2°
F
W B
Outdoor: 95°
F
DB/75.2°
F
W B
Indoor:68°
F
DB
Ou t door : 44.6°
F
DB/ 42.8°
F
WB
16.4in
3.Sensors list
type Description Qty
Ambient sensor Its used for detecti 1 edis roodtuo fo erutarepmet gn
Suction sensor
Its used for detecting suction pipe temperature of compressor to
adjust gas flowing
1
Defrosting sensor Its used for controlling outdoor defrosting at heating mode 1
1 taeh-revo fo esac ni rosserpmoc rof desu stI rosnes gnigrahcseD
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3