WARNING
DANGER OF BODILY INJURY OR DEATH
TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY
ELECTRIC CONNECTIONS.
GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS.
Precautions for Electrical wiring
■ Electrical wiring work should be conducted only by authorized personnel.
■ Do not connect more than three wires to the terminal block. Always use round type crimped terminal lugs with
insulated grip on the ends of the wires.
■ Use copper conductor only.
Selection of size of power supply and interconnecting wires
Select wire sizes and circuit protection from table below. (This table shows 20 m length wires with less than 2%
voltage drop.)
Item
Model
Phase
Circuit breaker
Power source
wire size
(minimum)
(mm
2
)
Earth leakage breaker
Switch
breaker (A)
Overcurrent
protector
rated
capacity (A)
Switch
breaker(A)
Leak current
(mA)
1U24GS1ERA
1U28GS2ERA(S)
1U28HS1ERA(S)
1U36HS1ERA(S)
1U48LS1ERA(S)
1U60IS1ERA(S)
1 40 30 6.0 40 30
1U48LS1EAB(S)
1U48LS1ERB(S)
1U48IS1EAB(S)
1U48IS1ERB(S)
1U60IS1EAB(S)
1U60IS1ERB(S)
1U60IS2EAB(S)
1U60IS2ERB(S)
3 30 20 4.0 30 30
■ If the supply cord is damaged, it must be replaced by the manufacturer or itsservice agent or a similar qualied
person.
■ If the fuse of control box is broken, please change it with the type of T25A/450VAC;
■ If the fuse of control PC board is broken, please change it with the type of T3.15A/250VAC. But for 1U24GS1ERA,
1U28GS2ERA(S),1U28HS1ERA(S),1U36HS1ERA(S),1U48LS1ERA(S),1U48LS1ERB(S),1U48IS1ERB(S),1U60I
S1ERA (S),1U60IS1ERB(S), the type is T6.3A/250VAC.
■ The wiring method should be in line with the local wiring standard.
■ The power cable and connecting cable should be self-provided.
■ All the cables shall have got the European authentication certicate. During installation, when the connecting
cables break off, it must be assured that the grouding wire is the last one to be broken off.
■ The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should not
be no less than 3mm. Such means for disconnection must be incorporation in the xed wiring.
■ The distance between its two terminal blocks of indoor unit and outdoor unit should not be over 5m. If exceeded,
the diameter of the wire should be enlarged according to the local wiring standard.
■ A leakage breaker must be installed.