Outdoor Unit
327
Super Match
WARNING
The specication of power cable
For models 1U24GS1ERA,1U28GS2ERA(S),1U28HS1ERA(S), 1U36HS1ERA(S), 1U48LS1ERA(S),
1U60IS1ERA(S), 1U60IS2ERB(S) the power cable should be H05RN-F 3G 6.0mm
2
.
For models 1U48LS1EAB(S), 1U48IS1EAB(S), 1U60IS1EAB(S), 1U48LS1ERB(S), 1U48IS1ERB(S),
1U60IS1ERB(S), 1U60IS2EAB(S) the power cable should be H07RN-F 5G 4.0mm
2
.
Wiring procedure
1) Remove set screws on the side before taking off the front panel toward the direction.
2) Connect wires to the terminal block correctly and x the wires with a wire clamp equipped nearby the terminal
block.
3) Route the wires in a proper way and penetrate the wires through the opening for electrical wiring on the side
panel.
INTERCONNECTING WIRES MUST BE WIRED ACCORDING TO FIGURE BELOW. INCORRECT WIRING MAY
CAUSE EQUIPMENT DAMAGE.
SINGLE SPLIT SYSTEM UNITS WIRING DIGRAM
MAXI SPLIT SYSTEM UNITS WIRING DIGRAM
Note:
1. The master is the indoor unit which connect to a wired
controller,others are slaves,please purchase wired
controller separately for MAXI system.
2. For one MAXI split system there is only one master.
3. For the MAXI system with 2 or 3 indoor units, the
wiring method is the same with the diagram on the
left except for the indoor units quantity.
4. Make sure that the wire connection for all units in
MAXI system OK before running.