Electic Control and
Debugging
383
Super Match
Outdoor
LED
display
Error code discription
Round way cassette--- indoor display outdoor error code
use the timer and running lamp OR I.D. PCB LED
Timer lamp
ash time(I.D. PCB
LED5)
Running lamp
ash time(I.D. PCB
LED1)
32
Malfunction of gas pipe temp. sensor
for indoor unit A
5 2
33
Malfunction of gas pipe temp. sensor
for indoor unit B
5 3
34
Malfunction of gas pipe temp. sensor
for indoor unit C
5 4
35
Malfunction of gas pipe temp. sensor
for indoor unit D
5 5
36
Malfunction of gas pipe temp. sensor
for indoor unit E
5 6
38
Malfunction of module temp.sensor
Momentary power failure detection
5 8
39 Malfunction of condensing temp. sensor 5 9
40
Malfunction of liquid pipe temp. sensor
for indoor unit E
6 0
41 Malfunction of ‘Toci’temp. sensor 6 1
42 System high pressure switch off 6 2
43 System low pressure switch off 6 3
44
System high pressure protection.
Refrigerant overabundance,high
condensing temp. or malfunction of fan
motor.
6 4
45
System low pressure protection.
Refrigerant shortage,low defrosting
temp., or malfunction of fan motor.
6 5