EasyManua.ls Logo

Haier AB18CS1ERA - Page 386

Haier AB18CS1ERA
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
384
Super Match
Error code for Outdoor unit(3U 4U 5U) conneting the other compact design 4-way
cassette(AB*CS1ERA ,AB*ES1ERA) /Convertible unit/Duct unit
Outdoor
LED
display
Error code discription
Compact design 4-way cassette/Convertible unit/Duct
unit--- indoor display outdoor error code use the timer and
running lamp OR I.D. PCB LED
Timer lamp
ash time(I.D. PCB
LED4)
Running lamp
ash time(I.D. PCB
LED3)
1 Faulty of outdoor unit EEPROM
2 1
2 IPM overcurrent or short circuit
2 2
4
Communication failure between Module
and ECU
2 4
5 Module operated overload
2 5
6 Module low or high voltage
2 6
8
Discharging temperature overheating.
Lack of refrigerant, ambient temperature
too high or PMVs blocked.
2 8
9 Malfunction of the DC fan motor
2 9
10 Malfunction of defrosting temp. sensor
3 0
11
Malfunction of compressor suction
temp. sensor
3 1
12 Malfunction of ambient temp. sensor
3 2
13
Malfunction of compressor discharge
temp. sensor
3 3
15
Communication failure between
indoor&outdoor unit
3 5
16 Lack of refrigerant or discharging
3 6
17 4-way valve switching failure
3 7
18 Loss of synchronism detection
3 8
20 Indoor thermal overload
4 0
21 Indoor frosted
4 1
23 Module thermal overload
4 3
24 Compressor start failure
4 4
25 Module input overcurrent
4 5
26 MCU reset
4 6
27
Module current detect circuit
malfunction
4 7
28
Malfunction of liquid pipe temp. sensor
for indoor unit A
4 8
29
Malfunction of liquid pipe temp. sensor
for indoor unit B
4 9
30
Malfunction of liquid pipe temp. sensor
for indoor unit C
5 0
31
Malfunction of liquid pipe temp. sensor
for indoor unit D
5 1

Other manuals for Haier AB18CS1ERA