B.For strand wiring
(1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation to about 3/8”(1Omm) to expose
the solid wire.
(2) Using a screwdriver, remove the terminal screw(s) on the terminal board.
(3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.
(4) Position the round terminal wire, and replace and tighten the terminal screw using a screwdriver.
Fix connection cord and power cable at the cord clamp.
After passing the connection cord and power cable through the insulation tube,
fasten it with the cord clamp.
Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube.
Electrical requirement
Select wire sizes and circuit protection from table below. (This table shows 2Om length wires with less than 2%
voltage drop).
Item
Model
Phase
Circuit breaker
Power source wire
size (minimum)
(mm
2
)
Earth leakage breaker
Switch breaker
(A)
Over-current
protector rated
capacity (A)
Switch breaker
(A)
Leak current
(mA)
AC28ES1ERA(S)
AC36ES1ERA(S)
1 40 30 6.0 40 30
AC48FS1ERA(S)
AC60FS1ERA(S)
1 30 20 4.0 10 30
CAUTION
Match the terminal block numbers and connection cord colors with those of the outdoor unit. Erroneous wiring
may cause burning the electric parts.
Connect the connection cords rmly to the terminal block. Imperfect installation may cause a re.
Always fasten the outside covering of the connection cord with the cord clamp. If the insulator is chafed, electric
leakage may occur.
Always connect the ground wire.
The unit has default temperature compensation setting, please cancel it when oor standing installation
Connect indoor unit and outdoor unit
(1) Remove the cord clamp.
(2) Process the end of the connection cords to the dimensions shown in wiring diagram.
(3) Connect the end of the connection cord fully into the terminal block.
(4) Fasten the connection cord with a cord clamp.
(5) Fasten the end of the connection cord with the screw.