EasyManua.ls Logo

Haier AU052FPERA - [75-0, 75-4] Pressure difference between high pressure and low pressure is abnormal

Haier AU052FPERA
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
57
[75-0, 75-4] Pressure difference between high pressure and low pressure is abnormal
Check if high/ low pressure
sensor is connected well
Check if compressor wire is
connected normally
If wire of inverter compressor
are connected oppositely
If 4-way valve is
interconnected
Measure if there is voltage
U, V, W of compressor by
multimeter, and if it is normal
Replace inverter compressor
Re-connect
Correct compressor wire
Correct compressor wire
Replace 4-way valve
Replace inverter module
No
No
No
No
No
No
Yes
Yes
Yes
Yes