>a__WcU[S^ <[c >a`V[e[a`Wc
AU142AFBIA, AU182AFBJA
0010573913
POWER
SUPPLY
BR BL
NL
B
W
Y/G
R
5
R
Y/G
3
WB
21
W
B
P6
P4
P9
CN701
4
10
Y/G
1.FAN MOTOR
2.4-WAY VALVE
3.COMPRESSOR
4.RELAY
5.FUSE(30A/250V~)
6.COMP.TEMP.SENSOR
7.PIPING TEMP.SENSOR
8.AMBIENT TEMP.SENSOR
9.CAPACITOR
10.TERMINAL BLOCK
11.RECTIFYING BRIDGE
12.INDUCTOR
13.FUSE(2.5A/250V~)
14.FUSE(1A/250V~)
15.RELAY
16.FAN MOTOR CONTROLLER(OPTIONAL)
17.LOW PRESSURE SWITCH
18.HIGH PRESSURE SWITCH
TO INDOOR UNIT
GR
OR
NC
NC
NO
NO
2
1
15
BB
COM
COM
6
8
7
5
BL
4
3
13
BL
P102
GR
COM
M
GR
CN5
CN6
CN112
P1
CN101
1
16
P101
B
R
14
CN106
CN109
R
P
CN502
R
W
N
U
2
CN107
0.1uF
R
R
BL
GR
18
R
P
17
12
P
11(2)
B
R
7
R
6
R
W
9(1)X2
200uF
250V
B
W
9(2)
2500uF
400V
B
3
R S T
B
8
R
11(1)
CN111
CN110
V
CN105
CN501
CIRCUIT DIAGRAM OF OUTDOOR UNIT
P3
P5
P2
-227-