CN1:second side of transformer
CN2:high pressure switch
CN3
:outdoor ambient temperature sensor
CN4:primary side of transformer
CN5:control port of 4-way valve
CN6
:control port 2 of compressor(not available for some models)
CN7
:control port 2 of compressor 1
CN8
:control port 2 of fan motor (not available for some models)
CN9:control port 1 of fan motor
CN10:low pressure switch
CN11:compressor discharging temp. sensor
CN12: outdoor coil temperature sensor
S:connection port for communication between indoor and outdoor
L1、L2、L3:power supply terminal(herein, no L2, L3 for single phase compressor)
N:port for neutral wire
TEST
:port for compulsory running, herein, on ZR side, short connecting the two pins
can enter the compulsory heating; on ZL side, short connecting the two pins can enter
the compulsory cooling.
CT1
:current detector
LED1
:outdoor LED
>a__WcU[S^ <[c >a`V[e[a`Wc
Ports on PCB functions for AU242AHBEA~AU88NATBEA
-270-