EasyManua.ls Logo

Haier AU182AFBJA - Indoor Unit

Haier AU182AFBJA
365 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
>a__WcU[S^ <[c >a`V[e[a`Wc
9.3 Indoor unit
AB092/122/142/182ACBIA,
AC092/122/142/182ACBIA, AD092/122/142/182AMBIA, AB14/182ACBEA,
AC14/18/242ACBEA, AD14/182AMBEA
CIRCUIT DIAGRAM OF INDOOR UNIT
0010576546
(FREEZE)
CN8
SW2
BL
P13
(HUMI)
(PUMP)
(HEAT)
Y
(L)
(FRESH)
P8 P9
P7
P12
P10
P11
(COMM)
W
(N')
(M)
(H)
SW3
P17
(L')
P14
P15
SW5
SW4
P16
CN4
CN17
CN5
MOTOR
FILTER
CN1
TRANS.
SWITCH
(DOOR)
(CONTROLLER)
WIRED
CONTROLLER
(FLOAT)
CN15
CN13
(UP-DOWN)
(12V/ALM)
CN14
A
B
(ALARM)
CN16
(REMOTE)
CN11
CN12
FLOAT
REMOTE
RECEIVER
REMOTE
CN2
P
CN1
MC1
COM
MC2
N
ON
12
ON
1234
CN19
CN20
3
W:WHITE B:BLACK
R:RED Y:YELLOW
OR:ORANGE BL:BLUE
BR:BROWN
Y/G:YELLOW/GREEN
TRANS.:TRANSFORMER
FG
L
CONTROLLER
CENTRALIZED
R
BL
B
B
W
FUSE T2.0A/250VAC
(RECEIVE
BOARD)
(SWING)
(OXYGEN)
OR
Y Y
M
SWING
MOTOR
M
FAN
MOTOR
M
2
11
1
4
8
7
9
10
CN21
CN7
FUSE
T3.15A/250VAC
P4(N2)
POWER SUPPLY
M
P5(N3)
TO OUTDOOR UNIT
R
2
3
1
B
W
L
BR
BL
N
Y/G
W
R
B
W
B
Y/G
OR
P1(L)
P2(N)
P3(N1)
FAN CAP.
Y/G
MOTOR
MOTOR
M
SWING
PUMP
R
P6(N4)
SW1
@
@
12
(ROOM/PIPE)
CN6
TEMP.
SENSOR
SENSOR
PIPING TEMP.
ROOM
6
5
13
M
M
ON
1234
ON
1234
ON
1234
6.PARTS AND CONNECTED WIRES IN DASHED FRAME 11 ONLY FOR AC142/182/242ACBEA
7. PARTS AND CONNECTED WIRES IN DASHED FRAME 12 DETERMINED BY PRODUCTS TYPE
8. IN AC242ACBEA, DASHED LINES MARKED @ CONNETED TO "1 , 2" ON TERMINAL BLOCK,
AND THERE ARE NO LINES BETWEEN "1 AND L" , "2 AND N"
9. REFER TO OPERATION MANUAL TO SET SW1-SW5
NOTE:
1. PARTS 1 2 3 ARE NOT
AVAILABLE
2. PARTS 4 5 6 ARE
OPTIONAL, AND THE LINE
MARKED 13 ONLY AVAILABLE
IN CONVERTIBLE TYPE
3. PART 7 NOT AVAILABLE
IN DUCT TYPE
4. PARTS AND CONNECTED
WIRES IN DASHED FRAME 8
ONLY FOR AB14/182ACBEA
5.PARTS AND CONNECED TWIRES IN DASHED FRAME 9 10 ARE NOT AVAILABLEIN AD14/182AMBEA,
AND
CONVERTIBLE TYPE,AND CORRESPONDINGLY THERE IS A CLIP ON PCB
AB242/28N/36N/42N/52NACBEA, AC28N/36N/42N/52NAFBEA, AD242/28N/36N/42NAMBEA,
AD242AMBIA
CIRCUIT DIAGRAM OF INDOOR UNIT
0010576547
(FREEZE)
CN8
SW2
BL
P13
(HUMI)
(PUMP)
(HEAT)
Y
(L)
(FRESH)
P8 P9
P7
P12
P10
P11
(COMM)
W
(N')
(M)
(H)
SW3
P17
(L')
P14
P15
SW5
SW4
P16
CN4
CN5
CN1
TRANS.
SWITCH
(DOOR)
(CONTROLLER)
WIRED
CONTROLLER
(FLOAT)
CN15
CN13
(UP-DOWN)
CN14
A
B
(ALARM)
CN16
(REMOTE)
CN11
CN12
FLOAT
REMOTE
RECEIVER
ON
12
ON
1234
CN19
UP-DN L-R
CN20
3
W:WHITE B:BLACK
R:RED Y:YELLOW
OR:ORANGE BL:BLUE
BR:BROWN
Y/G:YELLOW/GREEN
CAP.:FAN MOTOR CAPACITOR
TRANS.:TRANSFORMER
(RECEIVE
BOARD)
(SWING)
(OXYGEN)
OR
Y Y
M
SWING
MOTOR
FAN MOTOR
2
12
1
5
8
9
7
CN21
CN7
FUSE
T3.15A/250VAC
P4(N2)
M
P5(N3)
TO OUTDOOR UNIT
R
2 31
B
W
W
R
B
W
B
OR
P1(L)
P2(N)
P3(N1)
MOTOR
MOTOR
SWING
PUMP
R
P6(N4)
SW1
(ROOM/PIPE)
CN6
TEMP.
SENSOR
SENSOR
PIPING TEMP.
ROOM
6
4
Y/G
Y/G
10
14
13
M
M
CAP.
Y/G
Y/G
M
11
CAP.
M
ON
1234
ON
1234
ON
1234
6.
PARTS AND CONNECTED WIRES IN DASHED FRAME
12 13 ONLY AVAILABLE IN AC***AFBEA TYPE
7. REFER TO OPERATION MANUAL TO SET SW1-SW5
1. PARTS 1 2 3 IN DASHED FRAME ARE NOT AVAILABLE
2. PARTS 4 5 6 ARE OPTIONAL, AND THE LINE MARKED 14 ONLY AVAILABLE IN CONVERTIBLE TYPE
3. PARTS AND CONNECTED WIRES IN DASHED FRAME 7 9 ARE NOT AVAILABLE IN CONVERTIBLE TYPE,
AND CORRESPONDINGLY THERE IS A CLIP ON PCB
4. PARTS AND CONNECTED WIRES IN DASHED FRAME 8 ARE NOT AVAILABLE IN DUCT TYPE
5. PARTS AND CONNCETED WIRES IN DASHED FRAME 10 11 DETERMINED BY PRODUCTS TYPE
CN17
(12V/ALM)
NOTE:
REMOTE
CONTROLLER
CENTRALIZED
-231-

Table of Contents