POWER SUPPLY CORD 
Wiring Requirements 
•   115 Volt, 60Hz, 15-amp fused grounded 3 prong outlet 
•   The use of a time-delay fuse or time-delay circuit breaker 
is recommended. 
•   Use a dedicated circuit only. 
NOTE: Do not operate any other electrical appliances on 
this circuit or you may trip the circuit breaker/fuse. 
If this power supply cord is damaged, it cannot be repaired. It 
must be replaced with a cord from the product manufactur-
er. If the power supply cord is damaged call Haier Customer 
Service: 1-877-337-3639.  
To test the power supply cord before operation: 
1.    Plug the power cord into a grounded 3 prong outlet. 
2.    Press the Test button, and then press and release the 
   Reset button to restore power.  
REQUIRED GROUNDING METHOD 
This air conditioner must be grounded. The air conditioner is 
equipped with a power supply cord that has a 3 prong grounding 
plug. The power supply cord must be plugged into a mating, 
grounded 3 prong outlet, and grounded in accordance with all 
local codes and ordinances.  
115V 
15  Amp  
INSTALLATION REQUIREMENTS 
WARNING  
Electrical Shock Hazard 
Plug into a grounded 3 prong outlet. 
Do not remove the ground prong from the power cord 
plug. 
Do not use an adapter. 
Do not use an extension cord. 
Failure to do so can result in death, re or  electrical 
shock.  
ELECTRICAL REQUIREMENTS  
TOOLS AND PARTS 
Gather the required tools and parts before starting 
installation. 
PARTS SUPPLIED  
Exhaust Hose
Hose Connector
Hose Connector
Cover #5
Window Panel and 
 Extension Panel (3)
LOCATION REQUIREMENTS 
•   Place the air conditioner on a at, level surface in a 
location that is at least 20” (51 cm) from any wall. 
NOTE: The recommended distance from the window for 
optimal performance is 31.5 inches.  
•   Maintain a minimum 20” (51 cm) clearance around the air 
conditioner to not block airow. 
•   Keep the air conditioner free of any obstructions such as 
drapes, curtains, blinds, etc. 
•   The exhaust hose should be free of any obstructions. 
•   Do not place the air conditioner on an unstable or raised 
surface because it could fall and cause damage or injury. 
•   Do not place the air conditioner in direct sunlight or near 
a heat source such as baseboard heaters, stoves, etc. 
•   The window panel can be installed in a window with a 
minimum 20” (51 cm) to a maximum 40” (101.6 cm) 
opening.  