SERVICE MANUAL
Model: HRF-628AF6/IF6
21
Issue 2013-04-07
REF. Ref1304S001V0
5-7. Water inlet quantity setting
1. Under locked mode ,press“Func.Set”+“Ice on/off” for 3 sec.FRZ display “ET”,REF display any digital
between 35 to 85,every time you press “Ref.Temp” .REF display will reduce 5 and till it display
35.Every time you press “Frz.Temp”,REF display will increase 5 and till it display 85.
2. Every 5 is equal to 0.5 sec.