5-5. Self-testing function
1.Force start:Under locked mode, press Set-->Ref.Temp-->OK-->Frz.Temp”(ADBCA) one by
one within 5 sec. then press “Set”,and the REF and RFZ display icon will display T1,T1)
2.Forced defrost :
Keep the current state ,and press “Set” ,T2 will be present, then enter forced
defrost mode.
3.Quit:Keep the current state, press “Set” ,then will be present T3T4back to normal display
control,and escape from test mode.
MODE WORKING CONDITION
Force start
1)R and F display areasT1T1
2)Compressor start work
3)Freezer FAN work with high votage
Cooling FAN work with high votage
4)defrost heater off
5)REF air damper open
Forced
defrost
1)R and F display areasT2T2
2)Enter defrost mode
compressor OFF
Freezer /Cooloing FAN OFF
Defrost heater work
if the D-SNR 7D HTR work 10 sec and then quit test 2 mode;
if the D-SNR7D HTR will keep working until the D-SNR 7, and then quit test 2 mode;
3REF air damper keep close
Quit
Keep the current state, press “Set” ,then will be present T3T4back
to normal display control,and escape from test mode.