Domestic Air Conditioner 
18
5.1.3.8 Rated Operation
Rated Cooling: 
When receiving the instruction of indoor unit rated operation, the unit will start rated cooling operation.   
Rated Heating: 
When receiving the instruction of indoor unit rated operation, the unit will start rated heating operation.
 
 
5.1.3.9 IFP 
Press the remote control to select and enter the human perception mode; the panel will display the 
human perception symbol. Two wind velocity modes are available: fixed velocity and adjustable 
velocity. The specific options and control functions are as follows: 
Judge the position of the human being to have air flow control.   
Follow or Avoid may be set by the remote controller. When signals are detected for 10 seconds 
continuously in any area, humans are determined to be in the area and the air conditioner will enter 
auto control.   
(1) When signals are detected in a certain zone:   
ķ Wind direction following  Detect the area where human beings are and adjust the deflector to 
blow conditioned air towards the human body;   
 
When humans are detected in Zone A: See Position 4   
When humans are detected in Zone C: See Position 7. 
 
ĸ Wind direction avoiding  Detect the area where human beings are and adjust the deflector to 
blow air away from the human body.   
 
When humans are detected in Zone A: See Position 6     
When humans are detected in Zone C: See Position 5.   
 
(2) When humans are detected in both areas: