9
l
Thelow-temperature
alarmtoleranceerror
occursfrequently.
l
Heater terminal short
circuiterror
is dis-
played.
l
Thetipscannotbeclosed.
•The tips will not return to the
originalposition.
CHECK:Isthetiptoosmallfortheitemsto
beremoved?
ACTION
:Useatipwithalargethermal
capacity.
CHECK:Isthesettingvalueforthelow
temperaturealarmtolerancetoo
low?
ACTION
:Increasethesettingvalue.
CHECK:IsthetipforMODELFM-2023?
ACTION
:TurnthepowerswitchOFFandin-
sert the correct MODEL FM-2023
tip.TurnthepowerswitchON.
CHECK:Is there a foreign object between
thetips?
ACTION
:Removeit.
l
Tip error
or is
displayed.
ACTION
:Contact your Hakko representa-
tive.