HA1000 Switch Settings
The switches on the control boards are used to set functions and test operations. There
are three slide switches and one pushbutton switch located on the control boards. The
three slide switches are labeled #1, #2, and #3 while the fourth pushbutton switch
(SW4) is labeled “Carrier Recall”. Momentarily pressing SW4 recalls the carrier to
this end of the tube system.
Standard switch settings for Customer mounted control board
SW1 Switch 1: Blower Run Time Set. “Off” is normal setting. Switching “On”
enables blower “Time-Set” mode. See “Blower Run Time Set” for full
instructions on setting blower run times.
Activate “Turbine Test Mode” by holding SW4 while switching SW1
“On” if customer door is open and turbines are connected to this control
board. Send and teller call will activate the pressure and vacuum turbines.
If SW3 is turned on before SW1, the unit will enter “Door Test Mode”
which allows send and teller call buttons to operate the customer door
motor open and closed.
SW2 Switch 2: Turbine Mode. “Off” is normal setting with single stage
turbine. “On” is normal setting with multi-blower turbine systems.
SW3 Switch 3: Unit Selection. “Off” is normal setting for board mounted in
customer unit.
Standard switch settings for Teller mounted control board
SW1 Switch 1: Diagnostic Mode. “Off” is normal setting. Switching “On”
enables “Door Test Mode” which allows send and recall buttons to operate
the teller door motor open and closed.
Activate “Turbine Test Mode” by holding SW4 while switching SW1
“On” if teller door is open and turbines are connected to this control board.
Send and recall will activate the pressure and vacuum turbines.
SW2 Switch 2: Turbine Mode. “Off” is normal setting.
“On” is normal setting for CM2 teller only.
SW3 Switch 3: Unit Selection. This switch has been removed and permanently
fixed in the “On” position.