Multimeter 
DSO8000E Series HandHeld Oscilloscope User Manual                                                                                                75 
 
Figure 7-12 Relative Measurement 
Selecting Automatic/Manual Range Adjustment 
The default range mode of the instrument is automatic range. Suppose you are using the   
DC voltage mode, to switch to the manual range, perform the following steps: 
1) Press F3 key to enter the manual range mode and then Manual is displayed on the top of the 
 screen. 
2) Under the manual range mode, the measuring range is increased by a stage when pressing F4  
key each time, and when reaching the highest stage, it jumps to the 
lowest stage by pressing F4 key once again. 
3) Press F3 key to switch back to the automatic range mode and then Auto is displayed on the top  
of the screen. 
Attention: capacitance measurement without manual range mode. 
Then,the screen will look like the following figure 7-13.   
 
Figure 7-13 The Manual Range Mode