Menu and Control Keys 
 
 
All the keys are described as follows: 
Scope: Oscilloscope mode. 
DMM:Multimeter mode. 
AWG:Waveform generator. 
Menu:Function menu. 
Trig:Trigger setting menu. 
Enter: In scope, save the user-defined settings of the oscilloscope; 
In generator, press the button to confirm after entering the character. 
Auto:  It  automatically  adjust  the  horizontal  and  vertical  scales  of  the  oscilloscope 
automatically and set the trigger coupling, type, position, slope, level and mode, 
etc., to acquire a stable waveform display. 
Channel: Channel setting menu. 
Time: Horizontal setting menu. 
Zoom and move keys:   
In the trigger menu, the left and down keys push the trigger level down, and the 
right and upper direction keys push the trigger level up; 
In the channel menu, the upper and  lower direction keys change the zero level 
position of the channel, and the left and right direction keys change the volt/div of 
the channel; 
In the time base menu, the upper and lower direction keys change the time/div, and 
the left and right direction keys change the horizontal trigger position; 
In DMM, switch measurement function; 
In generator, after choosing a parameter, the left and lower direction key will reduce 
the parameter value,  the right  and  up direction  key will  increase  the parameter 
value; it is also used for the digital selection of the virtual keyboard. 
F1/F2/F3/F4:  Multi  function  key,  in  each  menu  mode,  is  responsible  for  selecting