12
1) OUT : This display indicates the output value of Heating model.
2) HEAT OUT : This display indicates the heating output value of Heating/Cooling model.
COOL OUT : This display indicates the cooling output value of Heating/Cooling model.
3) SV : This display indicates the set value that currently being monitored and programed during PROG or FIX Mode.
This display indicates the minimum value of setting range during RESET mode.
4) PID : This display indicates PID GROUP number that currently being controlled.
5) AUTO/MAN : This display indicates the output mode that currently being monitored. Use key to change
the required output mode during manual (MAN) mode.
3) Reset
1) Auto Mode, Heating model
2) Auto Mode, Heating/Cooling model
3) Manual Mode, Heating model 4) Manual Mode, Heating/Cooling model
① SV : This display indicates the minimum value
of setting range.
② ℃ : This display indicates the current temperature unit.
③ PT : This display indicate the current Pattern
(Use key to change the required pattern type)
④ SEGNO : This display indicate total number of programmed
segments and END.SEG of the current pattern. (END.SEG / Total SEG)
※ Total SEG and END.SEG
•If the latest programmed SEG is larger than ENG.SEG, Total SEG displays END.SEG.
•If END.SEG is same to/or larger than the latest SEG, Total SEG displays the latest programmed SEG.
【Ex. 1】 If 10SEGs are programmed while END.SEG is 8SEG, then Total SEG is 8SEG.
【Ex. 2】 If 5SEGs are programmed while END.SEG is 7SEG, then Total SEG is 5SEG.
【Ex. 3】 If 5SEGs are programmed while END.SEG is OFF, Total SEG is 5SEG.
●
Output (OUT) Display