INITIAL INSTALLATION
1. Turn off the circuit breakers and the wall switch to the
fan supply line leads.
DANGER: Failure to disconnect the power
supply prior to installation may result in serious injury or
death.
2. Determine the mounting method to use.
Standard mounting is best suited for ceilings 8 ft. or
higher. For taller ceilings you may want to use a longer
downrod (sold separately).
Angle mounting is best suited for angled or vaulted
ceilings. A longer downrod is sometimes necessary to
ensure proper blade clearance. Important: If using the
angle mount, check to ensure the ceiling angle is not
steeper than 16°.
Closemount-style mounting is more suitable for
ceilings lower than 8 ft.
Flushmount installation is not available for this item.
Standard Mounting
Flushmount Closemount
Angle Mounting
3. Ensure the blades (L) will be at least 30 in. from any
obstructions. Also check the downrod (A) length to
ensuretheblades(L)willbeatleast7ft.abovetheoor.
3
7 ft.
Minimum
30 in.
Minimum
A
L
1
2