44 HARDI
®
NAVIGATOR 550M, 800M, 1000M CENTRIFUGAL OPERATOR'S MANUAL
* Standard mesh
5.2 Filters
IMPORTANT:
Wear protective clothing when servicing & handling
components that have been in contact with spray liquid.
Clean fi lters ensure :
• Sprayer components such as valves, diaphr agms and operat ing unit are
not hindered or damaged during operation.
• Nozzle blockages do not occur while spray ing.
• Long life of pump. A blocked suction filter will result in pump
cavit ation.
ISO Nozzle
Size
Suction Filter
(optional)
Inline Filters
(optional)
Nozzle
Screen
Pressure
Filter
Pink (075)
Orange (01)
Green (015)
Yellow (02)
50 100 100 100
Lilac (025)
Blue (03)
50 80 80 80
Red (04)
& Larger
30* 50* 50* 50*