*High temperature warnings are canceled as soon as temperature returns to normal. If temperature reaches
cutoff level, the warning is replaced by a cutoff error message.
Error messages
Error messages indicate that a problem is present. The MAC Aura XIP communicates errors as follows:
Error messages flash in the display.
If more than one error is detected, the fixture flashes all errors three times each.
Errors are shown in the display regardless of display status: they override an inactive display and any
other information that the display might be showing.
If an error is present, the status LED flashes red.
The possible error messages are listed in Table 6 below:
UITW* UI TEMP HIGH
User interface (LCD display and control panel) PCB sensor detects
abnormally high operating temperature.*
WTTL WET TOO LONG
Fixture has been wet for an extended period. To remove the
warning, a complete dry-off procedure is required, especially before
storing/transporting the fixture or re-using it in wet conditions. To dry
off the fixture, move it to a dry location, wipe it with a cloth to remove
pooled water and then activate the DRY OFF program in the
SERVICE menu. Check that the fixture is completely dry before
storing it.
Short code Long message Explanation
ACER AURA CALIB ERROR Aura calibration data not found.
BCER BEAM CALIB ERROR Beam calibration data not found.
BETC BEAM TMP CUTOFF Beam PCB temperature cutoff activated.
BETE BEAM TMP SEN ERR Beam PCB temperature sensor error.
CELD COM ERR LED DRV LED driver communication error.
CEPN COM ERR PAN Pan communication failure.
COLD FIXTURE COLD
Fixture too cold. Physical movement of effects is disabled until
fixture has warmed up.
FAN BASE FAN ERR Base cooling fan error.
FAN HEAD FAN ERR Head cooling fan error.
FAN YOKE FAN ERR Yoke cooling fan error.
FBEP PAN FBACK ERR
Pan position magnetic indexing system timeout. Fixture is unable to
correct pan position (but pan movement will often still be possible).
FBET TILT FBACK ERR
Tilt position magnetic indexing system timeout. Fixture is unable to
correct tilt position (but tilt movement will often still be possible).
MMER MISSING MODULE ERR
Impossible to communicate with a module that should be present.
Module missing or not correctly connected.
PAER PAN ERROR Pan position electrical indexing system timeout.
PFTC PFC TEMP CUTOFF Power factor correction system temperature cutoff activated.
PFTE PFC TEMP SEN ERR Power factor correction system temperature sensor error.
PSER PAN TEMP SEN ERR Pan motor temperature sensor error.
PTCM P/T SENSOR ADJUST Pan/tilt sensors are incorrectly adjusted.
PTTC PT TEMP CUTOFF Pan/tilt PCB temperature cutoff activated.
PTTE PT TEMP SEN ERR Pan/tilt PCB temperature sensor error.
SEER ARTNET SOURCES EXCEED Number of Art-Net control sources exceeded.
Table 6: Error messages
Short code
Long message Explanation
Table 5: Warning messages

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman Martin MAC Aura XIP and is the answer not in the manual?

Harman Martin MAC Aura XIP Specifications

General IconGeneral
BrandHarman
ModelMartin MAC Aura XIP
CategoryFlood Light
LanguageEnglish